DCEC 16-400kW

AGEN AC DCEC Series diesel generator sets range from 16kW to 400kW (Standby).

DCEC engine applies to various application scenarios for insightful design of heavy-duty operation.

Its intelligent automatic controlling system improves the performance of engines. It features an effective mechanism designed to save energy and increase environmental compliance and therefore enables low fuel consumption, low emissions, and low noises. 3 layers of fuel filter ensure balanced particle dispersion protecting the main components of the fuel system.

Application
■ Construction engineering
■ Post offices & telecommunications
■ Shopping malls, skyscrapers
■ Hotels
■ Government agencies, schools

Category:

Features

 

  1. The corollary equipment has compact structure and flexible installation location
  2. High thermal efficiency, low fuel consumption (thermal efficiency 30~46%)
  3. Quick start with full loading. Great for dealing with emergency for full load due within 1 minute (normal 5~30MIN)
  4. Short shutdown process, can start and stop frequently
  5. Easy to maintain and operate
  6. Lowest overall cost of construction and power generation of diesel generator sets
50Hz
60Hz

*AC DCEC Series with Stamford / MPMC LYG / Leroy Somer
*All goods are sold in accordance with AGEN technical conditions of sales

3PH/50Hz 0.8 Power Factor
400V/230V as standard

Genset
Model
Genset
Standby Power
Genset
Prime Power
Brand New
DCEC Engine
Brand New
Alternator
Brand New
Alternator
Brand New
Alternator
kVA kWe kVA kWe Engine
Model
Emission Control Stamford LYG Leroy Somer
AC22-1 22 18 20 16 4B3.9-G11 NA M S0L2-G1 LYG 184E TAL-A40-F
AC30-1 30 24 27 22 4B3.9-G1 NA M S0L2-P1 LYG 184F TAL-A42-C
AC30-1 30 24 27 22 4B3.9-G2 NA E S0L2-P1 LYG 184F TAL-A42-C
AC44-1 44 35 40 32 4BT3.9-G1 NA M S1L2-R1 LYG 184J TAL-A42-F
AC44-1 44 35 40 32 4BT3.9-G2 NA E S1L2-R1 LYG 184J TAL-A42-F
AC63-1 63 50 56 45 4BTA3.9-G2 NA E S1L2-Y1 LYG 224DC TAL-A42-H
AC85-1 85 68 75 60 4BTA3.9-G11 NA E UCI 224G LYG 224FC TAL-A44-C
AC110-1 110 88 100 80 6BT5.9-G1 NA M UCI 274C LYG 274B TAL-A44-D
AC110-1 110 88 100 80 6BT5.9-G2 NA E UCI 274C LYG 274B TAL-A44-D
AC132-1 132 106 120 96 6BTA5.9-G2 NA E UCI 274D LYG 274C TAL-A44-E
AC150-1 150 120 135 108 6BTAA5.9-G2 NA E UCI 274E LYG 274D TAL-A44-H
AC170-1 170 136 155 124 6BTAA5.9-G12 NA E UCI 274G LYG 274E TAL-A44-K
AC200-1 200 160 180 144 6CTA8.3-G1 NA M UCI 274G LYG 274F TAL-A44-L
AC200-1 200 160 180 144 6CTA8.3-G2 NA E UCI 274G LYG 274F TAL-A44-L
AC220-1 220 176 200 160 6CTAA8.3-G2 NA E UCI 274H LYG 274G TAL-A44-M
AC265-1 265 212 250 200 6LTAA8.9-G2 NA E UCDI 274K LYG 274J TAL-A46-D
AC275-1 275 220 250 200 6LTAA8.9-G3 NA E UCDI 274K LYG 274J TAL-A46-D
AC300-1 300 240 270 216 6LTAA9.5-G3 NA E S4L1S-D4 LYG 314B TAL-A46-E
AC352-1 352 282 320 256 6LTAA9.5-G1 NA E S4L1S-E4 LYG 314DC TAL-A46-G
AC425-1 425 340 390 312 6ZTAA13-G3 NA E S4L1D-F4 LYG 314E TAL-A47-A
AC475-1 475 380 440 352 6ZTAA13-G2 NA E S4L1D-G4 LYG 354B TAL-A47-B
AC485-1 485 388 440 352 QSZ13-G2 NA ECM S4L1D-G4 LYG 354B TAL-A47-B
AC500-1 500 400 450 360 QSZ13-G5 NA ECM S4L1D-G4 LYG 354B TAL-A47-B
AC525-1 525 420 500 400 QSZ13-G3 NA ECM S5L1D-C4 LYG 354C TAL-A47-C
1PH/50Hz PF=1
220V/110V as standard
Genset
Model
Genset
Standby Power
Genset
Prime Power
Brand New
DCEC Engine
Brand New
Alternator
Brand New
Alternator
Brand New
Alternator
kVA kWe kVA kWe Engine
Model
Emission Control Stamford LYG Leroy Somer
AC18-1S 18 18 16 16 4B3.9-G11 NA M S0L2-G1 LYG 184E TAL-A40-F
AC22-1S 24 24 22 22 4B3.9-G1 NA M S0L2-P1 LYG 184F TAL-A42-C
AC22-1S 24 24 22 22 4B3.9-G2 NA E S0L2-P1 LYG 184F TAL-A42-C
AC35-1S 35 35 32 32 4BT3.9-G1 NA M S1L2-R1 LYG 184J TAL-A42-F
AC35-1S 35 35 32 32 4BT3.9-G2 NA E S1L2-R1 LYG 184J TAL-A42-F
AC50-1S 50 50 45 45 4BTA3.9-G2 NA E S1L2-Y1 LYG 224DC TAL-A42-H

Remarks

  1. Various Voltage available but coupled alternator model may be changed. For detailed inquiry, pls contact AGEN sales
  2. Stamford/TAL/Mecc alte Brushless Alternator available, Single Bearing, Flange Connection, IP23, Insulation Class H, Automatic Voltage Regulation (AVR Fitted)
  3. DSE4520/4620 as Standard; Comap AMF25 / DSE7320 for Option, ATS for Option
  4. With 8 Working Hours(@75% Loading) Fuel Tank, with AVM Suspension System, Set-mounted Exhaust System, Battery and Lead supplied
  5. With Chint main Circuit Breaker as Standard, ABB Breaker or Schneider for Option
  6. Complete Operation/Maintenance Manuals (in English) for Genset/Engine/Alternator, Genset testing report
  7. Warranty: 12 months or 1000 Working Hours from the shipment date, whichever comes first

*AC DCEC Series with Stamford / MPAC LYG / Leroy Somer
*All goods are sold in accordance with AGEN technical conditions of sales

3PH/60Hz 0.8 Power Factor
440V/254V as standard

Genset
Model
Genset
Standby Power
Genset
Prime Power
Brand New
DCEC Engine
Brand New
Alternator
Brand New
Alternator
Brand New
Alternator
kVA kWe kVA kWe Engine
Model
Emission Control Stamford LYG Leroy Somer
AC25-2 25 20 23 18 4B3.9-G11 NA M S0L2-M1 LYG 184E TAL-A40-G
AC34-2 34 27 30 24 4B3.9-G2 NA E S0L2-P1 LYG 184F TAL-A42-C
AC38-2 38 30 35 28 4B3.9-G12 NA E S1L2-J1 LYG 184F TAL-A42-E
AC50-2 50 40 45 36 4BT3.9-G2 NA E S1L2-R1 LYG 184H TAL-A42-F
AC70-2 70 56 65 52 4BTA3.9-G2 NA E S1L2-Y1 LYG 224DC TAL-A42-H
AC95-2 95 76 85 68 4BTA3.9-G11 NA E UCI 224G LYG 224E TAL-A44-C
AC115-2 115 92 105 84 6BT5.9-G2 NA E UCI 274C LYG 224G TAL-A44-D
AC145-2 145 116 132 106 6BTA5.9-G2 NA E UCI 274D LYG 274C TAL-A44-E
AC156-2 156 125 142 114 6BTAA5.9-G2 NA E UCI 274E LYG 274C TAL-A44-H
AC185-2 185 148 169 135 6BTAA5.9-G12 NA E UCI 274E LYG 274EC TAL-A44-K
AC210-2 210 168 190 152 6CTA8.3-G2 NA E UCI 274G LYG 274E TAL-A44-L
AC230-2 230 184 210 168 6CTAA8.3-G2 NA E UCI 274G LYG 274F TAL-A44-L
AC285-2 285 228 260 208 6LTAA8.9-G2 NA E UCDI 274J LYG 274H TAL-A46-C
AC315-2 315 252 285 228 6LTAA8.9-G3 NA E UCDI 274K LYG 274H TAL-A46-E
AC350-2 350 280 315 252 6LTAA9.5-G1 NA E S4L1S-D4 LYG 314B TAL-A46-E
AC425-2 425 340 388 310 6ZTAA13-G3 NA E S4L1D-E4 LYG 314D TAL-A46-H
AC475-2 475 380 438 350 6ZTAA13-G2 NA E S4L1D-E4 LYG 314EC TAL-A47-A
1PH/60Hz PF=1
220V/110V as standard
Genset
Model
Genset
Standby Power
Genset
Prime Power
Brand New
DCEC Engine
Brand New
Alternator
Brand New
Alternator
Brand New
Alternator
kVA kWe kVA kWe Engine
Model
Emission Control Stamford LYG Leroy Somer
AC20-2S 20 20 18 18 4B3.9-G11 NA M PI 144D LYG 184E TAL-A42-C
AC27-2S 27 27 24 24 4B3.9-G2 NA E PI 144E LYG 184G TAL-A42-E
AC30-2S 30 30 28 28 4B3.9-G12 NA E PI 144G LYG 184H TAL-A42-F
AC40-2S 40 40 36 36 4BT3.9-G2 NA E PI 144J LYG 224B TAL-A42-G
AC56-2S 56 56 52 52 4BTA3.9-G2 NA E UCI 224G LYG 224E TAL-A44-C

Remarks

  1. Various Voltage available but coupled alternator model may be changed. For detailed inquiry, pls contact AGEN sales
  2. Stamford/TAL/Mecc alte Brushless Alternator available, Single Bearing, Flange Connection, IP23, Insulation Class H, Automatic Voltage Regulation (AVR Fitted)
  3. DSE4520/4620 as Standard (From stock DSE3110 use up); Comap AMF25 / DSE7320 for Option, ATS for Option
  4. With 8 Working Hours(@75% Loading) Fuel Tank, with AVM Suspension System, Set-mounted Exhaust System, Battery and Lead supplied
  5. With Chint main Circuit Breaker as Standard, ABB Breaker or Schneider for Option
  6. Complete Operation/Maintenance Manuals (in English) for Genset/Engine/Alternator, Genset testing report
  7. Warranty: 12 months or 1000 Working Hours from the shipment date, whichever comes first

Additional information

Brands

DCEC